Application |
Dimensions/Weight |
1560mm (w) x 850mm(d) x 1900mm (h) / 1250Kg |
Power requirements |
AC 200-230 V ±10 % 3ф/30A (Note3) |
Air requirements |
0.5 MPa |
Max. Test area |
610mm x 510mm |
Board size |
50mm x 50mm - 620mm x520mm |
Board thickness |
0.1mm - 6 mm |
Specification |
Standard |
Option |
Min. Testing size
Note1 |
Pattern pitch |
40µm |
40µm (Note1) |
Pad size |
20µm |
15µm (Note1,2) |
Probe |
Probe heads |
4 Probe heads (2probes each side) |
Repeatability accuracy |
±1 µm |
Contact pressure |
2 -10 g (min) |
CCD camera |
4 Units ( 1unit /side) |
Isolation Test voltage |
1000V (max) (Note4) |
Low resistance Test current |
100mA (Typ) |
Test method |
Open detection (continuity test) Note5 |
Range: 0.1Ω - 10MΩ |
Short detection
(Isolation test) |
Range: up to 500MΩ max |
Range: up to 1GΩ max |
Capacitance measurement |
Comparison with master data |
4wire
Low.resistance.measurement |
Range: 0.1mΩ- 10KΩ
|
Resistance
Capacitance
Inductance
Embedded passive component test function Option |
Range: 0.1Ω to 1GΩ (Typ)
Range:1pF to 10uF (Typ)
Range:10uH to 100mH (Typ)
|
Data Management |
Input format |
IPC D 356A /MNF /Others |
Job Creator |
Job Creator Optionally available from Miyachi |
Test data preparation |
Smart Miyachi Optionally available from Miyachi |
Failure analysis |
Commercially available s/w |
Notes
1. Specified at room temperature = 23±3℃.
2. As the probing performance of machine, not as the specification including probe tip.
3. If an additional transformer, Automatic Voltage Regulator (AVR), etc. are required, please consult with us or our agent in the region.
4. Depending on the PCB under test, it requires to setup the right input voltage level.
5. Low Resistance measurement range not included.
6. Consult with us or our agent for the details.